Home
Product Catalog
Trade Leads
Contact Us
Product Catalog 
Product Catalog
Gas Generator
Gas Generator
Model No.︰HGT-300(500)E
Brand Name︰BeiJing
Country of Origin︰China
Unit Price︰-
Minimum Order︰1 pc

 Total 12 Related Items 
Prev89101112Next
Auto next page:   SecondsPlay

Product Description
 

HGA-2L (5L) Air Gas Generator

I.Summarize

The HGA-2L (5 L) Air Generator is to adopt the low noise compression engine to be the air source. This instrument has over voltage protection device and equipment with the temperature-controlled device purification system filter, the purifying system is composed of filter, activated carbon room and the silica gel room, it can effectively eliminate impurities in the air and water. Be used for kinds of home and abroad gas chromatograph, flame photometer, that it substitutes the cylinder to make your work more convenient.

II.Technical parameter

 

HGA–2L

HGA –5L

Air purity

three-level purification

Output flow rate

0-2 L/min

0-5L/min

Output pressure

A:0-0.4Mpa(connected with gas chromatograph)

B:0-0.5 Mpa(connected with Nitrogen Gas Generator)

Working condition

Supply voltage 220V 50HZ

Environmental condition

Temperature 15-40℃   Relative temperature ≤70%

The environment does not have the serious dust pollution,

Caustic gas.

Maximum work rate

150W

180W

Outlook size

490×240×380mm (L×W×H)

Weight

23

24

III.Instrument characteristic:

1. It can replace the traditional high-pressure air bottles, laboratory instrumentation.

2. Operate easily, only start power switch to be OK to produce gas, continuous use may also be discontinuous use.

3.System sets up the gas road for three-level purification.

4. Has two-stage stabilize voltage device, make it accuracy higher

5.Over voltage protection and drainage switch to make safety and convenient.

IV.Use method

1An instrument is taken out from package box, first examining that outward appearance and the inside have graveness or abnormal phenomena because of transportation or not, then checks power line, the accessory again being all in readiness or not.

2Accessories the "filter" to replace imported air behind the curtain blocking the plate, and the power cord socket inserted jail ensure safety.

3. On power source, the guiding light now is green, the piezometer instructs to rise gradually till 0.4 Mpa .After a few minutes the compression engine stops working, and the guiding light working becomes red. The A hermetic sealing nut whorl upper air of rear panel is exported relaxes, lets that have air displacement. Then the compression engine automation gets it in gear slightly, till stopping.

4All above OK, uses outside diameter 3 pipeline to link the exporting A to chromatographinsure not leakage. When working once again, need opening up switch being OK. (B output ports if not, please use the blind seal pressure cap.)

V.Matters needing attention

1That the course of working if guiding lights becomes green , pressure rises but less than setting value, in general is caused by two phenomena: First, the contents compressor thermal protection device was destroyed; Second compressor temperature is too high, the result is a lot of leakage, Soap Liquid comprehensive leak detection applications. Especially changing the silica gel should pay special attention to levels not screw extrusion ring department foreign bodies and to ensure that no leakage is OK to return to normal after cooling down, guiding lights becomes red.

2More water will affect air purity, so you must press the switch (the upper face ply red button) a few seconds to drain away water before shutting machine down every time; Pay attention to the waterspout direction, avoid power source electrical equipment.

3Observe the silica gel condition, change silica gel according to need from the side. Close a power source first replacement , a drying room is gone down according to clockwise sense whorl after pressure instructs to be zero, from taking out it from the instrument, again, having fallen cover , carried out replacement according to anti-clockwise whorl, afterwards, tighten , ensure that doing not leaking air .

4To ensure purity gas, need to replace an activated carbon (activated carbon for the 20-40 goals) after 1,000 hours working.  Before replacement, first cut off the power switch when the pressure is zero instructions, instrument hood open, then oil from the purification room equipped with activated carbon, counterclockwise spin, to replace activated carbon, then the opposite direction turn, ensure the seal no leakage.

VI.Special Attention

1Air system, the often green light working, belong to rate of flow is too big or have the blown phenomenon, respond to check leak in time; otherwise it will damage the machine!

2. Boot up empty gas equipment is strictly prohibited!

VII.Random attachment

1Seal off the pressure cap               M8х1                    2

2Rubber sealing gasket                 Φ6×1.9                   6

                                      Φ40×4                   4

                                   Φ16×4                   2

3Insurance                            10A                     1

4Power line                                                    1

5Filter                                                        1

6Operating instruction manual                                     1

7Certification                                                   1

VIII.Mass guarantee

Products produced by our company from the day of selling the products warranty for one year or free maintenance warranty period life-repair service. We repair all kinds of domestic and foreign gas chromatograph and gas generator and various laboratory equipment and other services; Chromatographic Analysis of the former Beijing Institute of Technology to continue taking up all the gas sales and repair and maintenance of equipment and operations to those of other laboratories to undertake design and construction of the gas pipeline project and other services; If the operator encountered in the course of product quality or technical advice. Please contact with the Beijing Huilong Changhai Trade Co. Ltd.

 

 

 

HGH-300E(500E) High Purity Hydrogenous Gas Generator

ISummarize

HGH -300E (500E) High Purity Hydrogenous Gas generator, is widely used in the domestic and foreign gas chromatograph; Widely used in the petroleum, the chemical industry, the coal, the medicine, food, the environmental protection, the health, the quarantine , the electric power, the public security, and laboratory analysis examination department and university.

IITechnical parameter

 

HGH–300E

HGH –500E

Hydrogen purity

99.999% (relative oxygen content)

Output flow rate

0-300 ml/min

0-500 ml/min

Output pressure

0.3Mpa(special pressure, please tell us)

Working condition

Supply voltage 220V 50HZ

Environmental condition

Temperature 0-40℃   Relative temperature <85%

The environment does not have the serious dust pollution,

Caustic gas.

Maximum work rate

180W

180W

Outlook size

360×190×380mm (L×W×H)

Weight

12

14

IIIInstrument characteristic

1. Operates easily, only must turn on the power switch, then produces the high purity hydrogen .Output pressure stabilizes and the LED numerical code shows is more eye-striking.

2. Only add distilled water for daily use. The instrument may be continuous use also discontinuous use.

3.Store liquid, produce hydrogen, let oxygen at the same time, pond warm low, also the life is longer.

4. This instrument is equipped with does not return fluid installment It can effectively guarantee the instrument not to have returned fluid phenomenon.

IVUse method

1.An instrument is taken out from package box, first examining that outward appearance and the inside have graveness or abnormal phenomena because of transportation or not, then checks power line, the accessory again being all in readiness or not

2. Preparation

 Preparation of electrolyte : 1.4 grams on analytical KOH (potassium hydroxide) diluted with 400 ml distilled water, KOH solution after cooling fluid to be injected into the pool (Volume largest pool of 1.6 L) ,then add distilled water to be below the level H line. (Removed the temporary pool lid at the top of equipment, it can be injected fluid; should be sealed when used for the transportation), covered with a pool lid before work.

starting switch, flow apparatus shown as follows

 HGH-300E type 0-300 ml/min

   HGH -500E type 0-500 ml/min

Start up the equipment, use the cap sealing pressure to screw to conveying output tightly, do not leak air,

2 minutes later, pressure instruct to be 0.3 Mpa, and the LED numerical code shows "000" approximation expressing an instrument is regular, otherwise blown, use the soap liquid leak hunting to remove.

The cap gets the hermetic sealing pressure on closing a power source , will convey output down , the pipeline and the chromatograph being put into use link and guarantee seals off an air tight with Φ3 pipeline and be sure not leakage . It is required to close power switch after working.

VMatters needing attention

1. Observe the silica gel condition, change silica gel according to need from the side. Close a power source first replacement , a drying room is gone down according to clockwise sense whorl after pressure instructs to be zero, from taking out it from the instrument, again, having fallen cover , carried out replacement according to anti-clockwise whorl, afterwards, tighten , ensure that doing not leaking air .

2. The instrument LED numerical code demonstrates value providing a reference only, it is to come from electrolysis electric current by changing, is also regular therefore rate of flow display has ±1 changes on ten-digital number

3The instrument needs to consume distilled water not KOH when working ,so it is only need to add distilled water for the daily use and be sure electrolyte place between H line and L line, (6-7 months changes electrolyte),

VISpecial Announcement

1When indicating pressure is low or digital display is bigger than ordinary, generally speaking is caused by the air leakage, then check all-round leak hunting with soap liquid, especially changing the silica gel should pay attention to more. 

2Boot up empty gas equipment is strictly prohibited! When not starting up for a long time should draw out electrolyte

VIIRandom attachment

1Sealing pressure apparatus                 M8х1              2

2Rubber O-rings                          Φ6×1.9            6

                                         Φ40×4             2

3Rubber gasket

Product Image
Gas Generator
Related Products
HPLC
HPLC
Hydrogen generator
Hydrogen generator
CNY ¥ 6600

Home  |  Product Catalog  |  Trade Leads  |  Contact Us  |  Sitemap
  简体版     繁體版     English
Powered by DIYTrade.com  Build your FREE website !